ProductDescriptionMastercool Part Number 55850IntellaSense Refrigerant Leak Detector KitIncludes:55800: Intellasense Refrigerant Leak Detector53513: LED UV Light92398: UV Safety Glasses2 D BatteriesLeak Test Vial and Replacement FiltersDetects:Combustible GasesHydrogenRefrigerants: All CFCs, HCFCs & HFCsMeets and exceeds J2791 (R134a), J2913 (R1234yf) and EN 14624The 55800 leak detector employs a new metal oxide gas sensor for the detection of chlorofluorocarbon gasses and blends. This tin oxide sensor is characterized by high sensitivity and a fast response, upon detecting the presence of extremely small levels of chlorofluorocarbon gases. Integrated into the design is a powerful microprocessor that automatically selects the best operating conditions for the sensor, to ensure optimum performance. The optimum sensor performance is maintained and monitored throughout the life of the sensor.Specifications:Sensitivity: High 0.15 oz/yr (4.25 g/yr)Medium 0.25 oz/yr (7 g/yr)Low 0.5 oz/yr (14 g/yr)Probe: Intelligent tip design that senses the condition of the environment, to eliminate the potential of false alarms, flexible 15.5″ probe for difficult to reach locationsDisplay:Progressive LCD with vertical bars corresponding to the magnitude of the detected leak, visual indication of the selected sensitivity rangeRefrigerants:Detects all refrigerants (CFC’s, HCFC’s, & HFC’s), unit has been tested and approved to work with R1234yf as well as R32 and R410aSensor Life:2000 hoursOperating Temperature Range:0-140FPower:Two (2) D BatteriesBattery Life:60 hours continuous use”Super Sensitive Function”:Allows the unit further sensitizing beyond the standard settings for locating small leaks with gases such as R1234yf and R407CLCD Features:Wait:This indication flashes whenever the unit is in the wait mode, this could occur whenever the unit is turned on or interference is detectedReady:This indication appears when the unit is ready for useInt: This indication appears whenever the microprocessor detects conditions that are not suitable for reliable leak detection, excessive wind blowing, blocked probe, burned out fan, or a missing or defective sensor that needs to be replacedBattery Symbol:When the battery symbol becomes illuminated this is an indication that the battery is low and needs to be replacedH-M-L:High, Medium, and Low sensitivity ranges will be displayed accordingly based on the selection made on the keypadSignal Level Bars:There are 10 vertical signal level bars on the display corresponding to the level of signal detected by the unitError Signals:E1 through E9 indicates diagnostic signalsKeypad Functions:On/Off:Press the ON/OFF button on the center of the keypad to turn the unit on or offVolume/Mute:Press the VOLUME/MUTE button to control the volume of the unitH M L Sensitivity:Pres the H M L SENSITVITY button to select the desired sensitivity levelHold:Press the HOLD button to freeze the signal bars, press the HOLD button again to disengagePeak:Press the PEAK button when multiple leaks are suspected as being present
There are no reviews yet.